Abstract
Context: Practitioners of manipulative medicine have long sought to prove the intra- and interexaminer reliability of palpatory examinations in assessing somatic dysfunction. However, decades of research have yet to achieve the level of reproducibility needed to satisfy evidence-based criteria.
Objectives: To examine the content validity of segmental motion evaluations using ultrasonographic measurements and to investigate the implication of these results for understanding the effects of an osteopathic manipulative treatment technique—high-velocity, low-amplitude (HVLA)—applied to somatic dysfunction in the lumbar spine.
Methods: A repeated-measures design was used, with the ultrasonographer blinded to the findings for each participant. The study was divided into 2 phases: (1) palpatory and ultrasonographic examination with no treatment and (2) palpatory and ultrasonographic examination with HVLA treatment. During phase 1, measurements were taken of tissue depth corresponding to bony landmarks of the dysfunctional vertebrae. Dysfunction was identified by means of palpatory examination and captured in sequential (ie, test-retest) ultrasonographic images. Content validity of somatic dysfunction was addressed by comparing palpatory examination with ultrasonographic data. During phase 2, the same protocol for tissue depth measurements was applied to the pre- and posttreatment images for comparison.
Results: Twelve young, healthy, asymptomatic students with no contraindications to HVLA treatment were recruited at Kansas City University of Medicine and Biosciences. The test-retest reliability, as determined by a Pearson correlation coefficient, was 0.997. For all participants, objectively identified side of dysfunction correlated with palpatory evaluation of segmental motion. A within-subjects analysis of variance was performed on the raw data, corrected for lumbar lordosis, showing statistical significance for main effect for side of measurement (P<.001) and interaction of side and time (P<.001), and showed no statistically significant effect for time (P=.259).
Conclusion: Ultrasonography is a reliable instrument for the assessment of somatic dysfunction of the lumbar spine. The data also establish the content validity of palpatory examinations. In addition, this study provides the first objective evidence, to our knowledge, of the effect of a thrusting manipulative treatment on dysfunctional lumbar vertebrae.
The concept of somatic dysfunction, or an alteration to the optimal mechanical state of the body with resultant effects to its functional capacity and surrounding structures,
1 is vitally important to practitioners of manipulative medicine. Somatic dysfunction is important because of its local effect on the body and its multifaceted effect on a patient's overall health.
2 The manipulative medicine research community has diligently sought an objective means to identify somatic dysfunction, focusing its effort on a standardized approach with independent verification. Without a consistent and reproducible diagnostic method, however, it is difficult to establish an evidence-based use of manipulative techniques to correct dysfunction.
3
Somatic dysfunctions are commonly identified by palpatory examinations. Criteria used for palpatory evaluation of somatic dysfunction include assessing for changes in the texture of adjacent tissues, asymmetry in bony position, restricted range of motion, and tenderness to palpation.
1,3 Throughout the early history of the osteopathic medical profession, somatic dysfunction was identified by components specific to each physician's respective understanding, creating a wholly unreliable basis for osteopathic research.
2 Johnston et al
4 pioneered the use of standardized protocols to detect somatic dysfunction—consisting of “deep tapping” (a percussion style of palpation), tape markers, and a light cloth that mapped the location of somatic lesions—which provided one set of approaches to which investigations could be calibrated. However, despite this enhancement in reliability provided by standardization and later consensus training,
5 a majority of the published protocols have failed to report a level of reproducibility (ie, results that are statistically similar among investigators and across populations) that supports the use of palpatory examination in evidence-based clinical practice.
5
Protocols were developed to remove aspects of variability from previous research through the use of instruments such as electromyography,
6,7 kinematic analyses,
8 myoelectric data,
9 and thermography.
10 Researchers sought to evaluate somatic dysfunction by using a more quantifiable method that incorporated these instruments as reference standards (also known as “gold standards”) to measure the same phenomena investigated by means of palpatory examination. These studies
6-10 attempted to assess the validity—defined by Najm et al
11 as the accuracy of a measurement of the true state of a phenomenon—of aspects of manipulative medicine, placing a special emphasis on content validity.
Content validity is the extent to which a measure adequately and comprehensively measures what it claims to be measuring,
11 assessed by the incorporation of a reference standard, which is a measure accepted as the best available for the assessment of particular phenomena. Because previous studies of manipulative medicine lacked acceptable reference standards,
11 however, the full potential of this avenue of research has remained elusive. Fortunately, continuous advances in medical technology have provided new modalities to address and surmount this issue.
Ultrasonography represents one such advance in medical technology. Ultrasonography stands apart from invasive procedures (eg, surgery, histopathology, angiography)
11 or radiography; it allows for the direct visualization of underlying anatomy through a noninvasive technology that is free of radiation exposure. A study by Fryer et al
12—which was, to our knowledge, the first to use ultrasonography for assessing palpatory examinations—compared readings of muscle thickness from paraspinal tissues that exhibited tenderness to palpation with nontender tissues.
Palpation remains a cornerstone of manipulative medical education curricula and a common technique used in clinical practice. The standard palpatory examination assesses for the asymmetrical change in position of the vertebra followed by motion testing for restriction of motion in 1 or more planes of motion.
1 Additional research is needed to confirm the reliability of palpatory examinations in identifying positional asymmetry. Such studies will begin to satisfy the requirements of evidence-based medicine and support the continued use of palpation examination in osteopathic medical education by demonstrating a reliable and reproducible way to assess motion restriction. Previous research,
5,11,13 however, has failed to demonstrate reliable evaluation of motion restriction. In the present study, we sought to examine the content validity of segmental motion evaluations by using ultrasonographic images and to investigate the implication of these results for understanding the effects of high-velocity, low-amplitude (HVLA) treatment applied to somatic dysfunction in the lumbar spine.
Participants were recruited from the freshman and sophomore classes of the student population at Kansas City University of Medicine and Biosciences' College of Osteopathic Medicine by announcement after daily lectures. We obtained approval from the university's Institutional Review Board. Exclusion criteria for the study included diagnosis of chronic back pain, spondylolisthesis, spondylosis, herniated nucleus pulposus, osteopenia, osteoporosis, osteophytic changes in the lumbar spine, and prior back surgery. For those who met the inclusion criteria, informed consent was obtained and demographic information was gathered from participants, including age, height, and weight.
All images in the present study depicted specific vertebral levels, as assessed by an ultrasonographer certified in cardiovascular and echo technology. The ultrasonographer ensured that soft tissue landmarks were uniform between subsequent images captured over time and, when scoring, the ultrasonographer measured the spinous process depth first, followed by the right and then left transverse process depths. The ultrasonographer relied on visual information, unaided by software, to correlate anatomic landmarks between images.
For phase 1 of the current study, participants underwent palpatory examination by means of the lumbar rotoscoliosis test,
15,16 which assesses the rotational motion of a vertebral segment. This test consists of the application of an anterior force applied alternately on the most lateral aspect of both transverse processes of each vertebral segment, while restriction and freedom of motion in the prone position were noted (
Figure 1). A physician (K.D.T.) who was board certified in neuromusculoskeletal and osteopathic manipulative medicine performed the assessment. When a somatic dysfunction was identified, the physician marked the dysfunctional vertebra bilaterally (
Figure 2) at its transverse processes for identification by the ultrasonographer, who was blinded to the specific diagnosis. Imaging was then performed at the particular level of dysfunction with the participant in the prone position by using the LOGIQ E9 Imaging System (GE Healthcare; Waukesha, Wisconsin), set to factory-established musculoskeletal imaging settings (
Figure 3). The participant's body was maintained in a constant position for ultrasonographic examination and subsequent imaging.
After the initial imaging, participants were assisted from the examination table to a standing position. The participants immediately returned to the prone position on the examination table for a second (ie, retest) image capture at the marked level of dysfunction.
After both (ie, test and retest) images were captured, the ultrasonographer measured tissue depths as seen on the ultrasonographic images (
Figure 4). Software included with the ultrasonographic imaging device was used to calculate the depth, in centimeters, from the superficial-most layer of skin to the most posterior aspect of the transverse processes of the dysfunctional lumbar vertebrae, bilaterally. The side demonstrating the shortest tissue depth was coded as the posterior transverse process, in accordance with the osteopathic postulates forming the foundation of palpatory examinations.
15,16 This same method was used to calculate the depth of the spinous process.
Statistical analyses were performed using IBM SPSS software (version 19; IBM Corporation, Armonk, New York). We computed test-retest reliability of ultrasonographic depth measurements by using Pearson product moment correlation. To assess content validity, the side of dysfunction identified at palpatory examination was compared with the most posterior side indicated by the ultrasonographic imaging. Means of the findings were calculated from test-retest findings.
The results indicate that ultrasonography can be a reliable method for the assessment and quantification of somatic dysfunction in the lumbar spine. Pearson correlation tests have a maximum value of 1.00, and our correlation of 0.997 indicates a very high degree of reliability for assessing tissue depth. Additionally, the correlation between palpatory examination of dysfunction and tissue depth measurements to identify the side of dysfunction revealed full concordance between the measures, providing support for the content validity of palpatory examination of segmental motion of the lumbar spine.
Phase 2 results indicated statistically significant side and side-by-time effects from data corrected for lordosis. The statistically significant results of the present study suggest that HVLA treatment improves segmental somatic dysfunctions as indicated by the return of restricted vertebra to a more symmetrical position as expressed by tissue depth measurements (
Figure 10). Our data support the use of the lumbar rotoscoliosis test
15,16 in palpatory examination; a central tenet of the test is that dysfunctional vertebrae are held in an asymmetrical position of rotation. However, we also note that the measurement of tissue depth, when corrected for lordosis, showed a uniform presence of left-sided somatic dysfunctions. These findings may reflect either an unknown bias in measurement or a common biomechanical response such as the “common compensatory pattern” described by Zink and Lawson.
18
Because the current study is, to our knowledge, the first attempt to use ultrasonography to assess the bony landmarks in palpatory examination, the possibility of a measurement bias cannot be excluded, particularly considering the magnitude of the depth being assessed. This potential for bias is compounded by the use of a single ultrasonographer for the collection and analysis of the ultrasonographic images. In an attempt to minimize the risk of bias, the ultrasonographer approached the imaging and image scoring in a reproducible, stepwise manner. Future studies could allay this bias by using multiple examiners to assess interexaminer reliability for image measurements and by incorporating more advanced ultrasonographic imaging software to limit measurement variability.
One limitation of the current study was the inability to validate tissue location for imaging. We were unable to use volume navigation technology, which enables the ultrasonographer to use global positioning system markers to more precisely mark and calibrate tissue locations. Future studies could use this technology to more accurately duplicate measurements, thus removing some of the traditional obstacles to observing the relationship between vertebral positional changes and HVLA.